Products

Our Ups

UPS Line interactive (200VA – 3000VA)

  • Selectable LED display or LCD screen.
  • Digital microprocessor control.
  • Boost and Buck AVR for voltage stabilization.
  • Automatic detection frequency.
  • Wide input voltage range.
  • Power-on self-test.
  • Cold start.
  • Automatic restart when mains power is restored.
  • Automatic utility phase tracking to ensure that the output voltage of the inverter at the same phase as the utility voltage, reducing transfer time and over voltage.
  • Intelligent battery management: battery temperature compensation to extend battery life; three-step charge to shorten the charging time.
  • Short circuit, battery overcharge / over discharge, overcharge, over voltage protections.
  • Automatic charging in OFF mode.
  • Optional empty shutdown.
  • Optional RS232 / USB communication port and RJ11 / RJ45 protection.
  • Unattended safety shutdown: system alarm and automatic power on / off via RS232 or USB interface communicating with the PC.

UPS en ligne avec transformateur (6kVA- 500kVA)

  • Single phase / single phase, three phase / single phase models with in-line double conversion technology.
  • DSP technology (Digital Signal Processors).
  • Suitable for all kinds of loads (resistive, inductive and non-linear loads, etc.).
  • High overload capacity (up to 150%).
  • Dual bypass DSP control design to improve reliability.
  • Support dual input, serial hot standby.
  • Redundant and parallelizable with advanced parallel current sharing control technology.
  • Cold start and mains start function.
  • High load capacity: 2 A / 4 A / 6 A / 8 A / 10 A / 12 A selectable (standard), 14 A / 16 A / 18 A / 20 A / 22 A / 24 A selectable (options).
  • Standard configuration with output isolation transformer
  • Superior protection (over-surges, short-circuit, over-voltage, under-voltage, overload, reverse connection protection, etc.)
  • Advanced communications (RS232 and USB ports (standard), SNMP, dry contacts and RS485 (options)).
  • Other options (parallel kits, input isolation transformer, bypass isolation transformer and harmonic suppressor).

UPS en ligne avec transformateur (6kVA- 500kVA)

  • High frequency in-line double conversion technology.
  • DSP (Digital Signal Processors) control technology.
  • Active Power Factor Correction (APFC), input power factor up to 0.99.
  • Output power factor 0.9.
  • Wide input voltage range (110V ~ 300VAC) and frequency range (40 ~ 70Hz).
  • Automatic detection frequency.
  • 50/60 Hz frequency conversion.
  • Cold start.
  • Rear ventilation design and variable speed fan.
  • Efficient software and hardware protection.
  • Fast and stable charging, capacity restored to 90% in 3 hours (standard UPS model).
  • Linear derating at low voltage input reducing battery discharge times.
  • Adjustable delayed start when power is restored.
  • Advanced Battery Management (ABM).
  • Several functions adjustable via LCD: output voltage, EOD, automatic start, bypass mode, ECO mode and frequency conversion mode.
  • M ulti-form communications: RS232 (standard), USB / RS485 / SNMP / dry contacts (optional).
  • Available options.
  • AlUSB option, RS485 card, AS400 dry contacts, SNMP card, SMS alarms, EPO function and 12 A charger (2/3 kVA only).

UPS Modulaire ( 20 kVA – 800 kVA)

  • High frequency line double conversion with DSP control.
  • Hot-swappable operation for all modules.
  • Integrated integrated PDU system, easy installation and economical initial investment.
  • Wide input voltage range, 50Hz / 60Hz automatic detection frequency.
  • Supports two frequency conversion modes: 50Hz input / 60Hz output and 60Hz input / 50Hz output.
  • Input power factor> 0.99, input THDi ≤ 3%, output THDV ≤ 5%.
  • Advanced “N + X” wireless redundancy and parallel technology allows different numbers of redundant UPS modules to be easily configured via the LCD display.
  • Integrated battery module available, 40 × 12 V / 9 Ah for each module.
  • Share battery in parallel operation, thus saving user battery cost.
  • System capacity up to 160 kVA / 160 kW built by each module 20 kVA / 20 kW, single charger module equipped with 30 A charging current, maximum 4 modules configured.
  • Flexible charger parameter and battery configuration parameter, selectable battery number: 32 pieces / 34 pieces / 36 pieces / 38 pieces / 40 pieces.
  • Advanced intelligent battery management technique, effectively extend the battery life.
  • Support battery cold start and automatic mains restart
  • Complete insulation between key components and the air duct effectively improves system reliability.
  • Maintenance accessible from the front, compatible with top / bottom cable entries.
  • Perfect protection for hardware and software (Class C lighting protection, circuit breaker, fuse, software and hardware protection), robust auto-sensing, plentiful event log for later monitoring.
  • 5.7 inch LCD touch screen, user-friendly human-machine interaction.
  • Standard emergency stop (EPO).
  • Standard RS232 / USB / RS485 / dry contact communication port.